Floor Build-up Renovation
![Floor build-up Renovation](/en/planning-service/System-Configuration/Renovation/EN-Fussbodenaufbau-Sanierung-rgb.jpg?resize=800fe5:732x&cid=ca.2ly)
Floor build-up 30 mm duct version A and B
![Floor build-up 30 mm duct version A and B](/en/planning-service/System-Configuration/Renovation/EN-Fussbodenaufbauten-30mm-AB-rgb.jpg?resize=03978b:732x&cid=cb.2m3)
- Outlet manifold
- Outlet grille
- Heating screed
- AIRCONOMY® system element
- Supplementary insulation EPS DEO 100/035–30 mm; R = 0,29 m.K/W; 100 kPa
- Noise dampening EPS-T 20-2; R = 0,44 m.K/W; 5 kPa
- Lower duct protective tape
- Lower duct 100 x 30 mm
- Folding panel AIRCONOMY®. 30 10.1.000 x 2.400 mm; R = 0,86 m.K/W; 100 kPa
- Concrete slab
Floor build-up 30 mm duct version C
![Floor build-up 30 mm duct version C](/en/planning-service/System-Configuration/Renovation/EN-Fussbodenaufbauten-30mm-C-rgb.jpg?resize=7e8525:732x&cid=cd.2ma)
- Outlet manifold
- Outlet grille
- Heating screed
- AIRCONOMY® system element
- Supplementairy insulation EPS DEO 100/035–30 mm; R = 0,29 m.K/W; 100 kPa
- Supplementairy insulation PUR E 20; R = 0,83 m.K/W; 100 kPa
- Lower duct protective tape
- Lower duct 100 x 30 mm
- Folding panel AIRCONOMY®. PUR 30 1.000 x 2.400 mm; R = 1,25 m.K/W; 100 kPa
- Concrete slab